BP100543 - 1275 Island Highway South -- Drawings Scanned/Attached
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP100543 - 1275 Island Highway South -- Drawings Scanned/Attached | |
|---|---|
| Neighbourhood: | Harewood |
| Street Address: | 1275 Island Highway South -- Drawings Scanned/Attached |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP100543 |
| Date Application Submitted: | May 22, 1998 |
| Application Description: |
Building Shell permit for Building. "A" 15022 sq ft, one storey, non-combustible, sprinklered, retail building. (3.2.2.43); Building "C" 2000 sq ft one storey, non-combustible, sprinklered gas kiosk with detached 2808 sq ft non-combustible, sprinklered gas-pump canopy (Part 9); and Building "D" 2800 sq ft non-combustible, sprinklered restaurant (3.2.2.19).Foundation for Bldgs A,B,C, and D are on BP# 100351. 1992 BCBC applies. buildings were permitted to be combustible As of 99-03-05 this building is A2 within 3.2.2.21, construction requirements are still OK, roof not rated for sprinklers. FV |
| Application Status: | COMPLETED |
| Permit Value: | $1,160,000.00 |
| Builder: | SOUTH PARKWAY PLAZA INC |
| Issued Date: | July 08, 1998 |
| File Close Date: | May 03, 1999 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 1275 ISLAND HIGHWAY S | CC3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
|
FIRELINE
Fireline for the sprinkler system must be complete and visable for inspection. |
PASSED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
FAILED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
|
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD | FAILED |
| OCCUPANCY-OLD |
PASSED
1999-05-03 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)