BP100130 - Laundromat at Southgate -Unit 114- 50 Tenth St. (Bob Deleau) -- Drawings Scanned/Attached

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP100130 - Laundromat at Southgate -Unit 114- 50 Tenth St. (Bob Deleau) -- Drawings Scanned/Attached
Neighbourhood: Harewood    
Street Address: Laundromat at Southgate -Unit 114- 50 Tenth St. (Bob Deleau) -- Drawings Scanned/Attached
Type of Application: Leasehold Improvements
File Number: BP100130
Date Application Submitted: January 16, 1998
Application Description: 97 S.M. "D" occupancy with occupant load of 20.-(3.2.2.39 of 1992 BCBC applies). FRR for walls, columns, load bearing walls is 45 min. Firewall to right of this occupancy and 45 min. FRR required for left wall . One (1) exit and 17 M. travel distance comply with Table 3.4.2.A. Combustible plumbing permitted provided it does not penetrate a fire separation or firewall. All combustible plumbing must be enclosed within a Gypsum Wallboard Membrane. No exit lighting is required. Emergency lighting is required.
Application Status: COMPLETED
Permit Value: $18,000.00
Building Area: 97.00 M2
1,044.10 ft2
Issued Date: February 27, 1998
File Close Date: May 01, 1998

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

1998-05-01

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.