BP100127 - Attached garage with loft
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP100127 - Attached garage with loft | |
|---|---|
| Neighbourhood: | Diver Lake |
| Street Address: | Attached garage with loft |
| Type of Application: | Garage / Carport Permit |
| File Number: | BP100127 |
| Date Application Submitted: | January 15, 1998 |
| Application Description: | To construct a 28ft wide by 24ft deep double garage addition with partial loft and three piece bathroom to the left side of this single family dwelling. |
| Application Status: | COMPLETED |
| Permit Value: | $18,862.00 |
| Building Area: |
63.82 M2 686.95 ft2 |
| Issued Date: | February 09, 1998 |
| File Close Date: | February 02, 2000 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 2323 ROSSTOWN ROAD | R5 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
LATERAL BRACING & SHEATHING
All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors. |
COMPLETED |
|
EXCAVATION
Excavation of soil, prior to placing forms. |
PASSED |
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured . For footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite. |
FAILED |
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured . For footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite. |
CANCELLED |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
FAILED |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
SANITARY CONNECTION
Pipe and connection must be visible for inspection. |
PASSED |
|
ROUGH IN PLUMBING
Pipe and connection must be visable for inspection. |
PASSED |
|
FRAMING
Rough-in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
|
PLUMBING FINAL
All fixtures must be in place. |
CANCELLED |
|
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
|
FINAL-OLD
Final Approval as per requested on plans. |
FAILED |
|
FINAL-OLD
Final Approval as per requested on plans. |
PASSED
2000-02-02 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)