BP116945 - 255 2000 Island Hwy -- Scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP116945 - 255 2000 Island Hwy -- Scanned | |
---|---|
Neighbourhood: | Departure Bay |
Street Address: | 255 2000 Island Hwy -- Scanned |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP116945 |
Date Application Submitted: | February 06, 2012 |
Application Description: |
Work BC - 335m2 Office use. Improvements include combining two existing suites into one, repair existing holes in fire separations between suites and between corridor and suite, install interior walls, ceiling and millwork, sprinkler changes. 2 hr firewall at right side and 1 hr suite separation at left. Mall suites are served by an existing "universal" washroom in the corridor. Brook Landing - 12,981m2 sprinklered building (fire alarm) with non-combustible and combustible construction divided by 2 firewalls under Equivalency. Equivalency required 1 hr fire separations between tenants. 4,980m2. firewall at Gridline 16 to southwest. 3.2.2.60 - 2006 BC Building Code applies: Group E occup, 45 min FRR floors, mezz if combustible. 0 min FRR roof. |
Application Status: | COMPLETED |
Permit Value: | $60,000.00 |
Builder: | BURKE (KC) CONTRACTING |
Issued Date: | February 21, 2012 |
File Close Date: | May 14, 2012 |
Associated Properties
Address | Zone | More |
---|---|---|
2000 ISLAND HIGHWAY N | CD8 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
CANCELLED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2012-05-14 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.