BP124937 - 219 - 4750 Rutherford Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP124937 - 219 - 4750 Rutherford Road | |
---|---|
Neighbourhood: | Rutherford |
Street Address: | 219 - 4750 Rutherford Road |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP124937 |
Date Application Submitted: | October 30, 2018 |
Application Description: |
Landlords work - combining existing CRU's 219 & 227, (future TD Call Centre), "D" office occupancy, 1135m2. Work includes update to HVAC services, removal of one demising wall & capping of existing plumbing, changes to fire alarm pull station location, new wall between corridor and suite with 2 hr fire separation, demising walls between this suite and existing North side suites upgraded on unit 219 side to a 2 hr FS, demising wall between unit 229 and 219 to be upgraded to a 1 hr FS. Building Classification: Group E building, BCBC 2012, 3.2.2.62, noncombustible construction sprinklered with fire alarm. REVISION: May 30/19 - Wall G5-2 changed from 2 hr FRR to 1 hr. FRR. |
Application Status: | COMPLETED |
Permit Value: | $60,000.00 |
Builder: | WINDLEY CONTRACTING (2010) LTD |
Issued Date: | March 12, 2019 |
File Close Date: | August 13, 2019 |
Expiry Date: | March 11, 2021 |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
APPROVAL-FIRE-OLD
Approval required prior to Occupancy |
COMPLETED |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2019-08-13 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.