BP120931 - 1918 East Wellington Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP120931 - 1918 East Wellington Road
Neighbourhood: Northfield    
Street Address: 1918 East Wellington Road
Type of Application: Commercial / Multi-Res Alteration
File Number: BP120931
Date Application Submitted: June 08, 2015
Application Description: Retrofit existing building. Existing building area = 378m2 - Existing Group F2, no change, Part 9 combustible , unsprinklered , no fire alarm, Adding one layer of 5/8" Type X to the existing roof joists to create a 45 min. FRR/FS. Adding two new demising wall each 45 min. FRR/FS terminated at the 45 min roof/ceiling assembly. Plumbing Rough-in for the Future universal washroom in Suite #103.
Complete Suite #101 (Universal Filters)and Complete Suite #102.(Storage for St Jeans Cannery) with New Universal washrooms, 2 required exits & emergency lighting.
Future tenant improvement permit required for Suite #103, this permit, roughin plumbing, two exits, emergency lighting.
Exterior upgrade: new rear and front exterior wall , metal siding and conc. curb, new OH doors and metal exit doors, new parapet .
Existing concrete block west wall face and east wall (left) (assumed 2 hr FRR exposed wall for east.)
Future permit required for tenant #103 and for exterior signage.
Application Status: COMPLETED
Permit Value: $40,000.00
Building Area: 378.00 M2
4,068.75 ft2
Builder: SEE THE FUTURE CONTRACTING
Issued Date: August 14, 2015
File Close Date: January 15, 2016
Expiry Date: August 14, 2017

Associated Properties

Address Zone More
1910 EAST WELLINGTON ROAD I1 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PARTIAL
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2016-01-15

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy