BP117599 - 605 Bowen -- Scanned

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP117599 - 605 Bowen -- Scanned
Neighbourhood: University District    
Street Address: 605 Bowen -- Scanned
Type of Application: Commercial / Multi-Res Alteration
File Number: BP117599
Date Application Submitted: July 24, 2012
Application Description: Auto Check Automotive - structural upgrades. Raising roof on portion of building. Existing Part Nine building, Group F2, one storey , unsprinklered , no fire alarm, 440.5 m2 Occupant load = 14 persons. single tenancy, Repair garage and ancillary spaces (office reception area) meet 9.10..9.17. No changes on the southwest side of the building between gridline D and F. installing new universal toilet room and relocating existing washroom plus two new sinks. Raising the structure on Northeast section of building structural changes. new wall along northeast 2 hr FRR. Rear south wall 2 hr FRR (infilling existing window openings with concrete block) , installing new doors and windows and adding parapet to existing. Repairing and new installation of stucco.
Application Status: COMPLETED
Permit Value: $95,000.00
Building Area: 440.50 M2
4,741.50 ft2
Builder: DOGWOOD MOUNTAIN HOMES LTD
Issued Date: August 27, 2012
File Close Date: January 22, 2013

Associated Properties

Address Zone More
605 BOWEN ROAD CC1 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
STORM CONNECTION

Pipe and connection must be visible for inspection.

PASSED
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2013-01-22

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy