BP128512 - 102-6421 Applecross Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP128512 - 102-6421 Applecross Road | |
---|---|
Neighbourhood: | Dover |
Street Address: | 102-6421 Applecross Road |
Type of Application: | Leasehold Improvements |
File Number: | BP128512 |
Date Application Submitted: | May 30, 2022 |
Application Description: |
Unit 102 - Tenant improvement (Fitness Experience) Group E (Retail). CRU (859 m2). Permit scope includes; addition of 2 Universal washrooms (2 toilets, 2 WB, 1 HWT), new emergency lighting, changes to sprinkler system (addition of two new sprinkler heads for washrooms), and changes to existing fire alarm (new manual stations and signaling devices). 1 Hr FRR/FS to adjacent lower floor retail suite to be maintained. 2 exits required. Max travel distance 45m. Existing mixed use commercial building. Original construction (1991) Part 3, Group E (retail), combustible and non-combustible construction, 2 storey, building area approximately 2026m2, sprinklered with fire alarm system. Previous work to create two Group E suites in lower floor under BP126101. |
Application Status: | COMPLETED |
Permit Value: | $25,000.00 |
Issued Date: | August 23, 2023 |
File Close Date: | August 29, 2024 |
Expiry Date: | August 23, 2025 |
Associated Properties
Address | Zone | More |
---|---|---|
6421 APPLECROSS ROAD | CC4 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
APPROVAL-FIRE
Approval required prior to Occupancy |
APPROVED |
FINAL
Final Approval as per requirements on plans. |
FAILED |
FINAL
Final Approval as per requirements on plans. |
PASSED
2024-08-29 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.