BP118540 - 203-1621 Dufferin Crescent
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP118540 - 203-1621 Dufferin Crescent | |
---|---|
Neighbourhood: | Northfield |
Street Address: | 203-1621 Dufferin Crescent |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP118540 |
Date Application Submitted: | April 18, 2013 |
Application Description: |
Millstone Medical Centre. New 3 storey shell medical building, office lease spaces and potential mercantile and assembly lease spaces on the ground floor, attached Parking Garage. Architectural and Structural drawings have been revised for DP approval. 2013-Sept-25. Refer to Permit Conditions limiting approval for the Parking Garage component of the building. Building designed to 3.2.2.65 Group E, 3.2.2.24, Group A2 and 3.2.2.59 Group D superimposed major occupancies. 3 storey, non-combustible construction, sprinklers and fire alarm. 1 hour rated floor assembly required above the first storey including supporting construction. O rating required above the second storey and roof. 1.5 hrs to parking garage. 2763 m2 total on 3 floors, with 1353m2 parking garage. |
Application Status: | COMPLETED |
Permit Value: | $3,200,000.00 |
Builder: | RW (BOB) WALL LTD |
Issued Date: | August 09, 2013 |
File Close Date: | September 08, 2014 |
Expiry Date: | August 09, 2015 |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
CANCELLED |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
SCHEDULED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2014-09-08 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.