BP124242 - 3018 Ross Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP124242 - 3018 Ross Road
Neighbourhood: Rutherford    
Street Address: 3018 Ross Road
Type of Application: Leasehold Improvements
File Number: BP124242
Date Application Submitted: March 20, 2018
Application Description: Tenant improvement with the combining of units 3018, 3018A, and 3018B into one unit addressed as 3018 (CruisePlus) Group D Occupancy. Building will now be occupied by a single tenant. Unit area is 280.9 m2 on the lower floor and 302.2 m2 on the upper floor, for a total of 583.1 m2. New plumbing work includes two new universal toilet rooms on the first storey, a new staff area sink on the first storey, and relocation of a dishwasher on the upper storey. Work also includes removal of two exit doors and fire alarm pull stations and installation of one new exit door and fire alarm pull station all from the first storey area

Part 9 Building: Building Area = 302.2 m2, Group D occupancy, two storeys, combustible construction, sprinklered with fire alarm system. 45 min FRR/FS for floor assembly, egress stairways, storey separation and loadbearing beams. Non-combustible columns on first storey are exempt from FRR under 9.10.8.11. (Part 3 as an Alternative) and 3.2.2.61.
Application Status: COMPLETED
Permit Value: $100,000.00
Builder: DOGWOOD MOUNTAIN HOMES LTD
Issued Date: June 15, 2018
File Close Date: August 23, 2018
Expiry Date: June 15, 2020

Associated Properties

Address Zone More
3018 ROSS ROAD COR3 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
PAPER/FLASHING/WATERPROOFING PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

CANCELLED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

CANCELLED
APPROVAL-FIRE-OLD

Approval required prior to Occupancy

COMPLETED
FINAL-OLD

Final Approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2018-08-23

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy