BP118463 - 2137 A Bowen Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP118463 - 2137 A Bowen Road
Neighbourhood: Northfield    
Street Address: 2137 A Bowen Road
Type of Application: Commercial / Multi-Res Alteration
File Number: BP118463
Date Application Submitted: March 21, 2013
Application Description: Change of use of the residential dwelling unit on the 2nd storey to a business and personal service use, Group D occupancy. Also, includes the first storey center of building conversion from Group C to Group D. The conversion area of the 2nd storey, Group D = 98.245 m2, 1 st storey = 44 m2. The area of the conversion on the first storey includes a garage that will be separated with a 1.5 hour FRR/FS and a 1 Hour door with a FPR and self closing device. Tactile warning system to be installed at the top of all stairways. Meets 9.9.4.7 exemption for construction of exit stairs. adding handrails to inside stairs and outside stairs. 1 hour FRR with noncombustible cladding on the Exposed wall face on left and right of 2nd storey includes attic. Existing fire ratings between suites

Part 9 buliding, Existing Group Eand Group D occupancies on the first story and second storey. Building area(Code) = 244.35m2, upper floor = 98.245 m2, Total floor area = 342.534m2
Application Status: COMPLETED
Permit Value: $2,000.00
Issued Date: June 10, 2013
File Close Date: September 05, 2013

Associated Properties

Address Zone More
2137 BOWEN ROAD COR3 Property Report

Process Steps

Task Status
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

SCHEDULED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FINAL-OLD

Final approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2013-09-05

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy