BP123990 - 101 - 104 5160 Dublin Way

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP123990 - 101 - 104 5160 Dublin Way
Neighbourhood: Pleasant Valley    
Street Address: 101 - 104 5160 Dublin Way
Type of Application: Leasehold Improvements
File Number: BP123990
Date Application Submitted: December 28, 2017
Application Description: Tenant Improvement to unit 103 (new Central Drugs Pharmacy) Group E Occupancy and upgrades in units 101-104 to provide 45 minute FRR to all columns. Unit 103 is 173.1m2, one universal toilet room (existing), 1 hour fire separations provided between unit 103 and adjacent tenants, 2 hour fire separation to parking garage below, Work also includes new fire rated interconnecting doors through non-structural fire separation wall to adjacent unit 104 (medical office) on magnetic hold open devices connected to fire alarm system and three new sinks.

Existing Building Classification - Group D, 3.2.2.61 facing 1 street, 2 Storey, sprinklered, 1hr FRR between suites, service room separated with 1hr FRR in walls and floor, suspended slab over (parking) storage garage 2 hr FRR required, 45min FRR wall assembly around elevator. Building reclassified under this permit to Group E, 3.2.2.67. which requires 45 minute FRR (min) upgrading of the columns.
Application Status: COMPLETED
Permit Value: $150,000.00
Builder: R.W. (BOB) WALL LTD.
Issued Date: March 23, 2018
File Close Date: May 16, 2018
Expiry Date: March 23, 2020

Associated Properties

Address Zone More
101   5160 DUBLIN WAY CD5 Property Report
102   5160 DUBLIN WAY CD5 Property Report
103   5160 DUBLIN WAY CD5 Property Report
104   5160 DUBLIN WAY CD5 Property Report

Process Steps

Task Status
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

CANCELLED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
OCCUPANCY-OLD PASSED

2018-05-16

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy