BP120209 - 102 1621 Dufferin Crescent

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP120209 - 102 1621 Dufferin Crescent
Neighbourhood: Northfield    
Street Address: 102 1621 Dufferin Crescent
Type of Application: Leasehold Improvements
File Number: BP120209
Date Application Submitted: September 30, 2014
Application Description: Code Brew - Unit 102- complete and occupy - 186 m2, Group A2, Occupant load 50 persons, 2 universal washrooms. Class 2 Cooking Operations (non-grease).

Existing FS/FRR installed under base building. 2 hr. FS/FRR Vertical suite separation provided between this unit and adjacent unit 103, 1 hr required D-A2 , 0 hr. FS/FRR public corridors, 1 hr. FRR/FS for floor assembly between 1st/2nd floors,

Building designed to 3.2.2.65 Group E, 3.2.2.24, Group A2 and 3.2.2.59 Group D superimposed major occupancies. 3 storey, non-combustible construction, sprinklers and fire alarm. 1 hour FRR/FS floor assembly required above the first storey including supporting construction. O Hr. FRR/FS required above the second storey and roof. 1.5 hrs FRR/FS to parking garage.
2763 m2 total on 3 floors, with 1353m2 parking garage(BCBC building area =2274 m2)
Application Status: COMPLETED
Permit Value: $150,000.00
Building Area: 186.00 M2
2,002.09 ft2
Builder: RW (BOB) WALL LTD
Issued Date: October 30, 2014
File Close Date: December 17, 2014
Expiry Date: October 31, 2016

Associated Properties

Address Zone More
1621 DUFFERIN CRESCENT CC5 Property Report
101   1621 DUFFERIN CRESCENT CC5 Property Report

Process Steps

Task Status
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2014-12-17

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy