BP119568 - 38 Victoria Crescent

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP119568 - 38 Victoria Crescent
Neighbourhood: Downtown/Old City    
Street Address: 38 Victoria Crescent
Type of Application: Commercial / Multi-Res Alteration
File Number: BP119568
Date Application Submitted: March 25, 2014
Application Description: Renovation to Existing 3 Storey, Part 9 building, BCBC 2012 Article 1.1.1.2 applies - 3 Storeys. The 1st and 2nd storey are considered one tenancy Group D and the 3rd storey is a separate tenancy Group C with subsiduary D. (Live/ work ). 1st storey, existing exit at rear, Group D = 148.6 m2; 2nd Storey,( Main floor) Group D = 148.6 m2, existing exit to front; 3rd floor, Group C with subsidiary D = 150.5 m2 with separated isolated exit to front of building . Providing a layer of 5/8" type X gypsum board to the floor /ceiling assembly between 1st and 2nd storey and an additional layer of 5/8" type x between the upper and main floor . Providing protection to the stairway. stair meets 3.2.8.2(6) interconnected floor space revised June 12, 2014
Application Status: COMPLETED
Permit Value: $110,000.00
Building Area: 447.70 M2
4,819.00 ft2
Builder: ALAIR HOMES
Issued Date: April 16, 2014
File Close Date: July 03, 2014

Associated Properties

Address Zone More
38 VICTORIA CRESCENT DT4 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
FOOTING/FORMS

Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2014-06-27

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy